Place of Origin: | Assembled In China |
Brand Name: | Fisher |
Model Number: | 67CFR-237 |
Minimum Order Quantity: | 10sets |
---|---|
Price: | Negotiation |
Packaging Details: | 1set packed in one carton ,each carton size is 23*13*9cm,0.8kg each one set. |
Delivery Time: | 3-8 work-days |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 1000sets Every Month |
Name: | 67CFR-237 Fisher Instrument Supply Filter Regulator | End Connetion: | 1/4" NPT |
---|---|---|---|
Inlet Pressure: | 250psi | Spring Range: | 0-60psi |
Pressure Gauge: | With Gauge | ||
High Light: | fisher regulator valve,fisher flow control valve |
67CFR-237 Fisher Instrument Supply Filter Regulator
Fisher 67CFR : filter regulators have an internal relief valve with a soft seat for reliable shutoff with no discernible leakage.
Fisher 67CFR-237 direct-operated regulators and filter regulators are typically used to provide constantly controlled, reduced
pressures to pneumatic and electropneumatic controllers and other instruments. These are suitable for most air or gas applications.
Other applications include providing reduced pressures to air chucks, air jets, and spray guns.
Types 67CFR-Filter Capabilities
Free Area: 12 times pipe area
Micron Rating: Polyethylene Filter (Standard): 5 microns Glass Fiber Filter (Optional): 5 microns PVDF or Stainless Steel Filter
(Optional): 40 microns
Drain Valve and Spring Case Vent Location
Aligned with inlet standard, other positions optional
Principle of Operation
Downstream pressure is registered internally on the lower side of the diaphragm. When the downstream pressure is at or above
the set pressure, the valve plug is held against the orifi ce and there is no flow through the regulator. When demand increases,
downstream pressure drops slightly allowing the spring to extend, moving the stem down and the valve plug away from the orifi ce.
This allows fl ow through the regulator.
Internal Relief (Fisher 67CFR model )
If for some reason, outside of normal operating conditions, the downstream pressure exceeds the setpoint of the regulator, the force
created by the downstream pressure will lift the diaphragm until the diaphragm is lifted off the relief seat. This allows flow through the
token relief. The relief valve on the Type 67CFR is an elastomer plug that prevents leakage of air from the downstream to atmosphere
during normal operation, thereby conserving plant air.
Available Configurations
End Connection | 1/4" NPT |
Maximum Inlet Pressure | 250 psig / 17.2 bar |
Spring Range | 0-125 psi/ 0-8.6bar |
Pressure Registration | Internal |
Smart Bleed Check Valve Set point | 6 psi / 0.41 bar differential |
Body Size and End Connection Style
1/4" NPT
Maximum Inlet Pressure (Body Rating)
250 psig / 17.2 bar
Outlet Pressure
0-60 psi
Pressure Registration
Internal
Temperature Capabilities
With Nitrile (NBR):
Standard Bolting: -20 to 180°F / -29 to 82°C
With Gauges: -40 to 180°F / -40 to 82°C
Contact Person: Mr. Barry Wang
Tel: +86-1391-318-7965
Fax: 86-512-66079692
2nd Stage R622 Model LPG Regulators Optional Spring Range For LPG Gas Fired Burner
Domestic Two Stage Gas Regulator High Precision Durable Cast Iron Body Sensus 496 Model
Sensus Model 243-12 High Flow Propane Regulator 125psi Pressure Reducing Valve
American Sensus Brand 143-80 Model Adjustable Propane Gas Regulator Industrial Use
HSR-CHGBLYN Fisher Propane Valves Cast Iron With 1 Inch NPT Globe Body
Gas Heating Equipment Fisher Gas Regulator Two Stage Compact Design
6000psi Fisher Controls Propane Regulator 1301F High Accuracy For Compression
FIsher EZR High Flow Rate Fisher Gas Regulator / Pressure Reducing Regulator With 161EB Pilot
Industrial EJA110E Differential Pressure Transmitter For Level Measurement
Non - Contacting Dp Transmitter For Flow Measurement , Pressure Transmitter With Display
High Performance Differential Pressure Transmitter Rosemount 3051CD Coplanar
Continuous Differential Pressure Level Transmitter Use In Hazardous Areas